Free ground shipping on orders over $250!
Happy Holidays! Conney Safety will be closed on Monday, December 25th and Monday, January 1st.
These rugged cord sets with single outlet offer instant ground fault protection and can turn any regular extension cord into a GFCI-protected cord. GFCI allows for a manual reset after a power interruption. Units is 15 Amp/125V rated and features a 12/3 STJW cord. Unit has a trip level of 4 - 6 mA. UL/CUL listed and OSHA compliant.
Use these OSHA-compliant industrial cord sets for any maintenance activities involving power tools and equipment. Cords are ruggedly made for indoor or outdoor use. Triple Outlet Cords provide GFCI protection to multiple devices. A bright red light indicates when the power is on. The test and reset buttons allow for periodic testing. GFCI automatically resets after a power interruption. Units are 15 Amp/125V rated and feature a 12/3 SJTW cord. All units have a trip level of 4 - 6 mA. All are UL/CUL listed and OSHA compliant.
Protect workers from electrical shock with Inline GFCI Cord Sets. GFCI requires a manual reset after a power interruption. Unit is 15 Amp/125V rated and features a 12/3 STJW cord. Unit has a trip level of 4 - 6 mA. UL/CUL listed and OSHA compliant.
Protect workers from electrical shock with Inline GFCI Cord Sets. GFCI automatically resets after a power interruption. Cord sets with triple outlet units are 15 Amp/125V rated and feature a 12/3 STJW cord. Unit has a trip level of 4 - 6 mA. UL/CUL listed and OSHA compliant.
Use these OSHA-compliant industrial cord sets for any maintenance activities involving power tools and equipment. Cords are ruggedly made for indoor or outdoor use. A bright red light indicates when the power is on. The test and reset buttons allow for periodic testing. GFCI automatically resets after a power interruption. Units are 15 Amp/125V rated and feature a 12/3 SJTW cord. All units have a trip level of 4 - 6 mA. All are UL/CUL listed and OSHA compliant.
GFCI User Attachable plug allows for a manual reset after a power interruption. Unit can be hard-wired to 12/3, 14/3 16/3 AWG STJW cords. Units are 15 Amp/125V rated, UL listed.
GFCI can be manually reset after a power interruption. Unit allows for user attachment of line and load side cords. Unit can be hard-wired to 12/3 AWG STJW cords for 20 amp or less applications. Units is 20 Amp/125V rated and has a trip level of 4 - 6 mA. UL/CUL listed and OSHA compliant.
Unit features a right angle GFCI plug and 4 outlets with separate covers for protection when not in use. Quad outlet box has an on/off rocker switch and an LED power indicator. 15 Amp circuit breaker provides over current protection. GFCI automatically resets after a power interruption. Unit is 15 Amp/125V rated and features a 12/3 STJW cord. Unit has a trip level of 4 - 6 mA. UL/CUL listed and OSHA compliant.
These rugged cord sets with single outlet offer instant ground fault protection and can turn any regular extension cord into a GFCI-protected cord. GFCI automatically resets after a power interruption. Unit is 15 Amp/125V rated and features a 12/3 STJW cord. Unit has a trip level of 4 - 6 mA. UL/CUL listed and OSHA compliant.
Cord Set features a 20-amp straight blade and connector. 20-amp plug is not compatible with 15-amp outlets or female connectors. GFCI must be manually reset after a power interruption. Units are 20 Amp/125V rated and feature a 12/3 STJW cord. Unit has a trip level of 4 - 6 mA. UL/CUL listed and OSHA compliant.
Plug this adaptor into any 3-prong outlet and convert it to a GFCI-protected outlet. GFCI automatically resets after a power interruption. Rated for indoor use only. Unit is 15 Amp/125V and has a trip level of 4 - 6 mA. UL/CUL listed and OSHA compliant.
GFCI User Attachable plug automatically resets after a power interruption. Unit can be hard-wired to 12/3, 14/3 16/3 AWG STJW cords. Unit is 15 Amp/125V rated and has a trip level of 4 - 6 mA. UL/CUL listed and OSHA compliant.
GFCI, or ground fault circuit interrupter, is a fast-acting circuit breaker that senses small imbalances in an electrical circuit caused by the electrical current leaking to ground. If this imbalance occurs, the GFCI shuts off the electricity within a fraction of a second. GFCI also protects against fires, overheating and destruction of insulation on wiring.